Panel 720

Panel 720 is complete solution for control, measurement and logging of casehole and openhole tools. It can operate all single conductor digital and pulse probes made in Novilog  and most probes from other manufacturers. Panel 720 can be used for logging, recording and analyzing of geological data.

Panel 720 consists of digital and analogue electronics circuits built in robust metal case. Panel 720 is primary designed for high speed microprocessor controlled digital communication, but it can also be used with impulse-type tools. Panel 720 is designed in combination with WellScan - user friendly data acquisition and log processing software, available for Windows and Linux based operating systems. Only line voltage is controlled by hardware, all other controls and adjustments are made in software.

SUPPORTED TOOLS:

  • Gamma and neutron probes
  • Caliper probe
  • Electrolog probes
  • CCL
  • Flowmeter (in hole and on surface)
  • Temperature Tool
  • Dual neutron
  • Velocity Tool
  • Merač dubine / Depth Tool
  • Orientation probe
  • Conductivity Tool
  • Spectrolog
  • Wide variety of impulse probes

Panel can be easily adapted to operate with large number of different probes from other manufacturers. Controls and adjustments are made in software.

Panel 720

TECHNICAL DESCRIPTION:

  • Enclosure: robust steel case
  • Dimensions: 205 mm x 200 mm x 80 mm
  • PC connection: USB
  • Operating (storage) temperature range: -10°C/+50°C (-20°C/+80°C)
  • Power consumption: 10 W, 230V AC
  • Power unit for tools :max. 140V , 200mA
  • Encoder input
  • Line signals:

Digital communication, compatible with Novilog tools, optional custom digital protocol (Manchester, etc)

Impulse communication - pulses

  • Borehole type: Open (water-filled)

Panel721

Winch Control Panel 042
Winch Control Panel 042

TECHNICAL DESCRIPTION:

  • Enclosure: robust steel case
  • Dimensions: 403 mm x 300 mm x 164 mm
  • PC connection: USB
  • Operating (storage) temperature range: -10°C/+50°C (-20°C/+80°C)
  • Power consumption: 10 W, 230V AC
  • Power unit for tools: max. 140V, 200mA
  • Encoder input
  • Line signals:

Digital communication, compatible with Novilog tools, optional custom digital protocol (Manchester, etc)

Impulse communication - pulses

  • Borehole type: Open (water-filled)

OPTIONAL:

  • custom case and connectors
  • custom power supply: 12V ili/or 24V DC
  • custom input signals: digital and analog