101 Impeller Flowmeter

Flowmeter is an acquisition device in robust case for bi-directional measurement of the rotation speed of a turbine wheel (impeller), related to flow of fluid inside the well. Data are are digitalized and send by digital communications to surface. This tool is designed for stationary measurements only.

TECHNICAL DESCRIPTION:

General:

  • Impeller cage size: 100mm
  • Tool length: 100cm
  • Detector position: 15cm from the bottom
  • Weight: 8 kg
  • Max. pressure: 20MPa
  • Temperature range: up to 85 °C
  • Output signal: digital
  • Power Consumption: 90Vdc/max. 90mA
  • Cable: Designed for single conductor cable
  • Borehole type : Open (water-filled)

Sensor type:

  • Hall sensors

Measurement Range:

  • 0.01 rev./s – 20 rev./s ; Angular resolution : 22.5°

Threshold Velocity:

  • 2 m/min

Optional:

  • Centralizer (recommended), custom diameter
  • Extended maximum working temperature: 125°C
  • Measurement range can be expanded to higher revolution speed.
  • Custom output signal (impulse, etc.)
  • Custom tool diameter(min. 30mm)
  • Custom tool head